Philips Heartstart FRX AED Trainer w/ Smart Pads Battery Features:
The Philips HeartStart FRx Defibrillator (“FRx”) is an automated external defibrillator (AED). Small, lightweight, rugged, and battery-powered, it is designed for simple and reliable operation by minimally trained users. The FRx is highly configurable for local protocol considerations.
The FRx is used to treat ventricular fibrillation (VF), a common cause of sudden cardiac arrest (SCA), and certain ventricular tachycardias (VTs). SCA is a condition that occurs when the heart unexpectedly stops pumping. SCA can occur to anyone – young or old, male or female – anywhere, at any time. Many victims of SCA do not have warning signs or symptoms. Some people may have a higher risk for SCA than others. Causes vary and may be different for infants and children than for adults.
VF is a chaotic quivering of the heart muscle that prevents it from pumping blood. The only effective treatment for VF is defibrillation. The FRx treats VF by sending a shock across the heart, so it can start beating regularly again. Unless this is successful within the first few minutes after the heart stops beating, the victim is not likely to survive.
BBEE1-5
Specifications
Size
2.4” H x 7.1” D x 8.8” W (6 cm H x 18 cm D x 22 cm W).
Weight
Approximately 3.5 lbs (1.6 kg) with battery and pads installed.
Pads compatibility
HeartStart SMART Pads II 989803139261 (In an emergency or during use, HeartStart DP series 989803158211 and 989803158221 pads may be used. However, the FRx should not be stored with these pads installed, as the daily self-test will not give a “pass” result and the device will chirp.)
Temperature and relative humidity
- Operating (battery installed, pads connected): 32° to 122° F (0° to 50° C); 0% to 95% RH (non-condensing).
- Standby (between uses with battery installed and pads connected): 32° to 122° F (0° to 50° C); 10% to 75% RH (non-condensing). Storage/shipping (with battery and pads case): -4° to 140° F (-20° to 60° C) for up to 1 week; 0% to 85% RH (non-condensing) for up to 2 days, thereafter 65% RH maximum.
Transient Operating (for 20 minutes or less, after the rapid transition from 68° F [20° C]): -4° to 122° F (-20 to 50° C); Under non-condensing humidity conditions.
Altitude
0 to 15,000 feet (0 to 4,572 m)
Atmospheric pressure
1013 hPA to 590 hPA.
Shock/drop abuse tolerance
Withstands 4 foot (1.22 meter) drop on any edge, corner, or face of the device onto the masonry surface.
Vibration
Operating: meets MILSTD 810G Fig. 5146E-1, random. Standby: meets MILSTD 810G Fig. 5146E-2, swept sine (helicopter).
Sealing
Meets IEC 60529 class IP55. Protected against jetting water from any direction per IEC 60529 class IPx5, and against access to hazardous parts and ingress of solid foreign objects (dust protected) per IEC 60529 class IP5x.