BioMedical-Cart Cart
0 item(s) items
Phone +1-800-910-1422
Hours of Operation: Mon. – Sat. 8:00 a.m. – 6:00 p.m. PDT
Philips PageWriter TC50 EKG

Philips PageWriter TC50 EKG

SKU: P/0520/P/0364/S
Certified Used
1-year Limited Warranty
Regular price
Price
$5,400.00
Unit price
per 
iso
  • iso
  • ohsas
  • guarantee

The Philips PageWriter TC50 is an easy to use portable cardiograph that’s tough, scalable, networked, and packed with features.

Supports clinical decision making with the Philips DXL ECG algorithm, providing industry-leading ECG interpretations and continuity and consistency throughout all PageWriter products and the IntelliSpace ECG management system.

The Philips PageWriter TC50 has excellent ECG interpretation, especially when it comes to pediatric and gender-specific analysis, pacemaker pulse detection, QT measurements, and brings an advanced suite of STEMI decision support tools to the table, helping guide the user through the treatment of patients experiencing chest pain.

Features

  • 16-Lead interpretation for a more complete view of heart activity
  • Quickly mark up to 10 different cardiac events for later review using only a single touch of the screen (within 20 minutes of patient's ECG)
  • Capture and store up to 10 minutes of continuous 16-lead data to capture both periodic and intermittent arrhythmias using full disclosure
  • Select any 10 second period for a fully interpreted report using Philips' DXL ECG Algorithm
  • Cardiac event data is automatically saved in a time capsule after 20 minutes
  • Import ECG orders with comprehensive patient information via IntelliSpace ECG (DICOM order manager, EMR)
  • CCX compliant support for open communication protocols like Cisco CCX and 802.11(a,b,g,n)
  • Easily acquire or input patient data via barcode scan, keyboard entry, worklist download, or patient search function
  • Easily configured to automatically print, save, transfer and retrieve any previous ECG
  • Easy 1-2-3 guided push-button sequence for users administering an ECG
  • Indicated for use with Adults, Pediatrics, and Neonates
  • Philips DXL ECG Algorithm offers superior ECG interpretations and provides a powerful suite of advanced STEMI decision making support tools
  • Philips’ scalable system streamlines your ECG workflow with wired and wireless connections via XML, HL7, & DICOM
  • 3-button workflow management: Connect leads, Enter ID, Take ECG
  • Anatomically designed Patient Interface Module makes attaching lead wires quick and intuitive
  • Color-coded lead traces and lead map make it easy to identify missing or poorly connected electrodes
  • 3-in-1 Trident lead wires minimize tangling issues
  • Large 10” touchscreen with print preview

 


Why choose A Biomedical Service as your Refurbishing Partner?

Beyond significant cost savings and a sound capital equipment investment strategy, A Biomedical Service believes your patients and medical staff deserve access to the highest quality, most reliable medical equipment. We're committed to delivering the level of excellence your facility needs to achieve its patient care and asset management goals.

We aren't simply your refurbishment company, we're your partners in managing capital equipment investment along every step of a piece of equipment's lifecycle.


Refurbished Equipment vs. Certified Used

What's the difference between a piece of used medical equipment that's been refurbished compared to one that's certified used?

Refurbished equipment and certified used equipment are both thoroughly cleaned and sterilized. Their sensitive data is properly disposed of and we make sure the equipment works the way the original manufacturer intended it to perform.

Refurbished Medical Equipment

A machine that's Refurbished goes through a rigorous process that takes each piece of equipment back to the original OEM specifications. Our in-house biomedical engineers are certified, experienced, and the best in the business.

Every item that needs to be restored is torn down to its component blocks, fully tested, and visually inspected. Using OEM parts, highly-trained Biomed engineers identify and replace components that have failed or are likely to fail. Think of it as a tuneup for used medical equipment.

If there's any damage to the case, it will be repainted or replaced. After reassembly, every unit is tested to make sure it meets stringent manufacturer requirements.

Certified Used Medical Equipment

Certified Used machines are also cleaned and sterilized. Their sensitive data is secured and legally disposed of. Our talented BMETs perform a series of thorough preventative maintenance procedures and test the units to make sure they meet OEM standards for operation. In this case, not all replacement parts may be OEM, however, the units will still reliably perform to original manufacturer specifications.


Need to sell your old medical equipment?

A Biomedical Service is always looking to buy used or pre-owned medical equipment. We have a friendly, experienced purchasing department that would love to help walk you through the asset disposal process.

Our goal is to make the asset end-of-lifecycle process as painless as possible, get you the best price for your equipment, and help you dispose of unwanted medical equipment in an ecologically responsible way.

If you're interested in selling your used medical equipment to A Biomedical Service, contact us here or give us a call at +1-800-910-1422, Monday through Saturday, 8 AM - 6 PM PDT. We look forward to talking to you!

 

Specifications

Refurbished & Used Certified with a Limited 1 year warranty

DIMENSIONS

  • Height: 12 in (31 cm)
  • Width: 16 in (40 cm)
  • Depth: 4 in (11 cm)
  • Weight: 21.6 lbs (9.8 kg)

POWER

  • AC Power: 100-240 VAC, 50-60 Hz
  • Power Consumption: <60 W
  • Batteries: Lithium-ion, rechargeable, hot-swappable; Volatage: 9-12.6 VDC; Current: 6.0 A max per battery, continuous use; Power Consumption: 33-55 W per battery (continuious)/54 W maximum per battery (2 sec peaks)
  • Battery Life: 45 min continuious Rhythm printing or up to 237 individual sheets of ECG recording paper
  • Time to Recharge: <5 hrs to 95% if in Standby mode; <8 hrs to 95% if cardiograph is in use

ECG FUNCTIONS

  • Simultaneous Lead Acquisition: Up to 18 leads
  • ECG Reports (12-lead):
    • 3x4, 3x4 1R, 3x4 3R, 3x4 1R plus ST Maps, 6x2, 12x1
    • Standard and Cabrera formats, plus Pan 12-Cabrera
  • ECG Reports (Extended Leads H22):
    • 3x4 3R ST, 3x5, 3x5 1R plus ST Maps, 3x5 3R, 4x4, 4x4 1R plus ST Maps, 6x3, 6x3 1R, 3x5 + 1x3 1R, 3x4 + 2x3 1R, 3x4 + 3x2
    • Standard and Cabrera format plus PAN 18 Cabrera
  • Rhythm Strips: Up to 18 configurable leads
  • Full Disclosure:
    • Ten minute history of all 18 leads
    • Complete ECG report of any 10 seconds
  • Event Marking:
    • Ten independent events can be marked for later review and analysis
    • Event markers appear on ECG reports
  • Timed ECG: Support for pharma stress protocols
  • Report Storage/Transfer: Full fidelity at 500 Hz of 10 sec for up to 18 leads
  • Data Format: PDF or XML, DICOM 12-lead ECG, and DICOM General ECG

ECG ALGORITHM

  • Type: Philips DXL 18-Lead ECG Algorithm
  • Interpretive Statements:
    • >600 interpretive statements
    • Integrated pediatric analysis
  • Leads Used in Diagnosis: Standard 12 leads plus V3R, V4R, V5R, V7, V8, and V9
  • Borderline Statement Supression: 3 Configurable settings
  • Standard Measurements:
    • Ten interval, duration, and axis measurements
    • Configurable QT correction method
  • Extended Measurements:
    • 46 measurements of morphology analysis in each of the 18 leads
    • 21 parameters of rhythm analysis
  • Reasons: Selectable explanations of all interpretive statements
  • Nomenclature: Aligned with 2007 AHA/ACCF/HRS Recommendations, Part II

STEMI CLINICAL DECISION SUPPORT

  • Graphical ST Presentation:
    • Five ECG reports with polar ST Maps
    • Frontal and transverse planes
  • Unique Right Heart Statements: 9 Statements called by right-chest leads
  • Unique Posterior MI Statements: 16 Statements called by posterior leads
  • Age and Gender Criteria: Based upon 2009 AHA/ACCF/HRS Recommendations, Part VI: Acute Ischemia/Infarction
  • STEMI-CA (Culprit Artery):
    • Criteria that suggest any of four probable sites of the occluded coronary artery
    • Based upon 2009 AHA/ACCF/HRS Recommendations, Part VI
  • Critical Values: Highlights four conditions requiring immediate clinical attention

DATA MANAGEMENT

  • Internal Storage: 200 ECGs
  • External Storage: 200 ECGs with optional USB device
  • FIPS Certification: FIPS 140-2 validated
  • Data Format: PDF or XML, DICOM 12-lead ECG, and DICOM General ECG

DISPLAY

  • Type: Integrated Backlit TFT-LCD SVGA Display
  • Waveforms: 12 Leads Displayed.
  • Screen Size: 8.3 in x 9 in (21.1 cm x 15.8 cm)
  • Resolution: 800 x 600 px, SVGA
  • Screen Navigation: Touchscreen navigation with physical keyboard

USER INTERFACE

  • Touchscreen: 1-2-3 streamlined operation; Context-sensitive application; 5-wire, resistive touchscreen
  • Keyboard: Backlit 1-2-3 buttons; 65-button, standard full alphanumeric keyboard with support for special characters; Silicone-based flexible keyboard cover

PATIENT CONNECTIONS

  • Patient Interface Module (PIM): Remote, microprocessor-controlled digital module with 5μV resolution; Acquire data at 8000 samples/sec per lead for 12/18 lead ECG
  • Long Lead Set: Longer length lead wires give users greater distance between PIM and patient connections
  • ST Numeric Resolution: 0.1 mm

NETWORK COMMUNICATION

  • Central Time Management: Manage time manually or automatically synchronize to a Network Time Server via IntelliSpace ECG or IntelliBridge Enterprise
  • Orders Worklist:
    • Download of orders worklist from networked server
    • User-configurable drop down lists (e.g., by location, user, or shift)
    • Ad-hoc query for specific orders based upon multiple user-entered or scanned search criteria (e.g., patient ID, last/first name)
    • Supported by Open Worklist with IntelliSpace ECG and select departmental systems
    • Supported by standard HL7 and DICOM interfaces via IntelliBridge Enterprise for departmental and hospital systems
    • Supported by DICOM modality worklist within DICOM MWL system
  • ADT (D02):
    • Query and retrieval of patient demographic information
    • Based upon user-entered or scanned search criteria (e.g., patient ID, last/first name)
    • Supported by standard HL7 interface via IntelliSpace Enterprise for hospital systems
  • Last ECG:
    • Automatic retrieval of previous ECG or list of available ECGs for current patient
    • Supported by IntelliSpace ECG
  • li>Interactive Query:
    • Retrieval of selected ECGs based upon user-entered search criteria
    • Supported by TraceMasterVue
  • Manual Orders: Create patient worklists with complete demographic information for later retrieval
  • DICOM ECG result output (D08):
    • Create DICOM 12-lead ECG
    • Generate DICOM General ECG

NETWORK CONNECTIVITY

  • Modem (H11): V.90, K56flex, enhanced V.34, V.32bis, V.32, V.22bis and below
  • Fax (included in H11): Group 3, Class 1 or 2 fax modem protocol
  • LAN: 10/100 Base-TX IEEE 802.3 ethernet via on-board RJ45
  • Wireless: (D21): 802.11(b/g), 802.11(i), WPA, WPA2; (D22): 802.11(a/b/g), 802.11(i), WPA, WPA2
  • Wireless Credential: Cisco compatible CCX v4

DATA MANAGEMENT

  • Internal Storage: 200 ECGs
  • External Storage: 200 ECGs with optional USB device
  • FIPS Certificate: FIPS 140-2 validated

AUTOMATED DATA INPUT

  • Bar Code Reader (H12):
    • Reads Code 39 Symbology
    • Flexible field data entry
  • Strong "IC" Card Reader (H14):
    • ISO 7816 and EMV 3.1.1
    • Supports SLE 4418/28 and SLE 4443/42

SIGNAL QUALITY INDICATORS

  • Leads Off Advisory: Anatomical lead map displays the location and label of loose or disconnected leads/electrodes
  • Lead Color: Four colors indicate the quality of individual lead connections
  • LeadCheck: Lead placement software tool that detects 20 different lead reversals to help prevent user error
  • Heart Rate: Continuous display of patient heart rate
  • Print Preview: Full-screen preview of ECG waveforms prior to printing

FILTERS

  • Pre-Processing Filters: AC noise: 50/60 Hz; Signal processing: Artifact Rejection and Baseline Wander
  • Presentation Filters (10 sec reports): High Pass: 0.05, 0.15, and 0.5 Hz; Low Pass: 40, 100, and 150 Hz

PRINTER

  • Type: High-resolution, thermal digital-array
  • Resolution: 200dpi (voltage axix) x 500dpi (time axis) at 25 mm/sec

ENVIRONMENTAL

  • Operating Temperature: 10 to 40˚C
  • Relative Humidity (Operating): 10 to 90%, non-condensing
  • Altitude: 0 m to 4550 m (15,000 ft)